Skip to main content
. 2019 Apr 29;12(9):1385. doi: 10.3390/ma12091385

Table 2.

Ra values (%) of the Cr–Mn–Ni–N–Cu austenitic stainless steel samples under different heat treatment conditions after the DL-EPR test.

Temperature (°C) Ra value (%)
10 min 30 min 60 min 120 min 300 min
900 0.70 ± 0.11 0.61 ± 0.14 0.80 ± 0.24 0.85 ± 0.17 0.75 ± 0.14
850 0.70 ± 0.01 0.76 ± 0.07 0.56 ± 0.10 0.33 ± 0.14 0.61 ± 0.12
800 0.47 ± 0.05 0.75 ± 0.17 3.55 ± 0.63 0.39 ± 0.08 1.90 ± 0.82
750 6.48 ± 0.05 19.87 ± 0.94 19.36 ± 0.11 31.30 ± 2.14 34.89 ± 1.64
700 5.97 ± 0.32 14.98 ± 0.95 20.00 ± 1.10 33.12 ± 2.37 39.97 ± 0.10
650 0.39 ± 0.13 1.68 ± 0.05 8.74 ± 0.27 19.48 ± 0.02 25.40 ± 0.47
600 0.42 ± 0.11 0.22 ± 0.05 0.22 ± 0.05 0.13 ± 0.04 1.73 ± 0.19