Skip to main content
. 2019 May 11;19(9):2183. doi: 10.3390/s19092183

Table 2.

Kinematic measurement (VT acceleration, velocity, and displacement) agreement between the HoloLens and HD/LB sensors. NRMSE-Normalized Root Mean Squared Error. Xcor-Cross Correlation Coefficient. All values reported as the mean and 95% confidence interval.

HoloLens vs. HD
A V D
STS NRMSE 9.60 (8.70,10.51) 4.83(4.22,5.45) 5.58 (4.29, 6.87)
Xcor 0.888(0.872,0.904) 0.979(0.975,0.983) 0.993 (0.989 0.997)
TUG NRMSE 10.53 (9.60,11.46) 6.16 (5.57,6.76) 19.56 (17.24,21.87)
Xcor 0.802 (0.770,0.834) 0.926(0.918,0.934) 0.998 (0.997 0.999)
HoloLens vs. LB
A V D
STS NRMSE 9.77 (8.29,11.25) 8.55 (6.98,10.12) 11.88 (9.72,14.03)
Xcor 0.765 (0.704,0.827) 0.900(0.851,0.949) 0.965 (0.949,0.982)
TUG NRMSE 8.48 (7.56,9.41) 7.68 (7.05,8.31) 14.07 (11.86,16.28)
Xcor 0.740 (0.695,0.786) 0.853 (0.835,0.872) 0.986 (0.978 0.993)