Skip to main content
. 2019 May 10;12(9):1541. doi: 10.3390/ma12091541

Table 6.

Characterization of mortar: flow after 120 min [cm], compressive strength after 3, 7 and 28 days [MPa], n = 6, Series 3.

Code Flow After 120 Min [cm] Compressive Strength [MPa]
3 days 7 days 28 days
REF 16.75 53.03 ± 2.35 63.94 ± 0.71 68.35 ± 6.7
CS_SOL_10% 10.5 15.19 ± 0.31 21.71 ± 1.33 28.62 ± 1.72
CS_SOL_40% 13 24.99 ± 1.1 34.64 ± 0.77 43.32 ± 0.40
CS_SOL_100% 16 49.90 ± 8.27 64.24 ± 1.45 77.1 ± 3.82