Skip to main content
. Author manuscript; available in PMC: 2020 May 1.
Published in final edited form as: Heart Rhythm. 2018 Nov 24;16(5):743–753. doi: 10.1016/j.hrthm.2018.11.026

Table 2B.

Changes in the Primary Response Variable from the SMART-AV Trial as a Function of Biomarker CRT Score*

Biomarker CRT Score Absolute Change in LVESV* Relative Change in LVESV+
0 −30 ± 39 −22.1% ± 30.5%
1 −25 ± 50 −15.7% ± 34.2%
2 −14 ± 43 −9.1% ± 35.4%
3 −13 ± 41 −6.9% ± 31.8%
4 −5 ± 36 −0.2% ± 25.9%
*

The Biomarker CRT Score when considered as 5 ordinal treatment groups, was associated with a significant difference in both absolute and percent changes in LVESV (absolute change: Cuzick trend test statistic=5.2, *= p<0.001; relative change: Cuzick trend test statistic=5.9, +p<0.001). Specifically, with a lower Biomarker CRT Score the mean decrease in LVESV was greater, whereas with a higher Biomarker CRT Score a much smaller mean decrease in LVESV occurred.