Table 4.

Summary of acoustic data collected for experimental condition

Source of Variation Experimental Condition
Jitter Shimmer SNR F0
15cmH20 + 0% Elongation 0.62 ± 0.37 3.96 ± 1.76 16.42 ± 5.07 192.07 ± 29.94
20cmH20 + 0% Elongation 0.69 ± 0.38 4.12 ± 1.97 16.26 ± 5.48 207.91 ± 32.67
25cmH20 + 0% Elongation 0.75 ± 0.61 4.41 ± 2.05 15.73 ± 4.58 226.74 ± 35.13
20cmH20 + 10% Elongation 0.77 ± 0.50 4.28 ± 2.00 15.62 ± 4.75 262.24 ± 53.86
20cmH20 + 20% Elongation 0.71 ± 0.39 3.97 ± 1.69 15.77 ± 4.50 333.04 ± 87.19