Skip to main content
. Author manuscript; available in PMC: 2020 May 29.
Published before final editing as: IEEE Trans Biomed Eng. 2018 Nov 29:10.1109/TBME.2018.2883958. doi: 10.1109/TBME.2018.2883958

TABLE III.

Comparison of PSNR and MAE values between Unet and Dense-Unet at different under-sampling ratios.

Reconstructed T2 with different models T1+1/4 T2 T1+1/8 T2 T1+1/16 T2
PSNR MAE PSNR MAE PSNR MAE
Unet 37.6 0.013 36.6 0.015 33.8 0.020
Dense-Unet 39.1 0.011 36.9 0.014 34.3 0.019