Skip to main content
. 2014 Jun 24;2014(6):CD006767. doi: 10.1002/14651858.CD006767.pub3

Comparison 2. Angioplasty versus stenting at 12 months.

Outcome or subgroup title No. of studies No. of participants Statistical method Effect size
1 Duplex patency 9 858 Odds Ratio (M‐H, Random, 95% CI) 1.78 [1.02, 3.10]
2 Angiographic patency 5 384 Odds Ratio (M‐H, Fixed, 95% CI) 1.30 [0.84, 2.00]
3 Ankle brachial index 4 441 Mean Difference (IV, Random, 95% CI) 0.03 [‐0.05, 0.11]
4 Treadmill walking distance 2 240 Mean Difference (IV, Random, 95% CI) 41.72 [‐102.34, 185.78]
5 Quality of life 1   Mean Difference (IV, Fixed, 95% CI) Totals not selected
5.1 Physical quality of life 1   Mean Difference (IV, Fixed, 95% CI) 0.0 [0.0, 0.0]
5.2 Mental quality of life 1   Mean Difference (IV, Fixed, 95% CI) 0.0 [0.0, 0.0]