Skip to main content
. 2019 Mar 15;52(3):262–268. doi: 10.5946/ce.2018.183

Table 4.

Previous Reports on Endoscopic Ultrasonography-Guided Gallbladder Drainage (studies with 10 cases)

Study n Histology Technical success, n (%) Clinical success, n (%) Procedural AEs, n (%) Stent type Mean follow-up (days)
Jang et al. [11] (2012) 30 Benign (30) 29 (97) 29 (100) 2 (7) NBT N/D
Choi et al. [12] (2014) 63 Benign/malignancy (22/41) 62 (98.4) 62 (98.4) 3 (4.8) MS 275
Takagi et al. [13] (2016) 16 Benign/malignancy (4/14) 16 (100) 16 (100) 0 (0) MS and PS 182
Tyberg et al. [14] (2018) 42 N/D 40 (95) 40 (95) N/D MS, PS N/D
Kamata et al. [15] (2017) 12 Benign/malignancy (1/11) 12 (100) 12 (100) 0 (0) MS 304
Choi et al. [16] (2017) 14 Malignancy (14) 12 (85.7) 11(91.7) 4 (28.5) MS 130
Irani et al. [17] (2015) 15 Benign/malignancy (9/6) 14 (93) 14 (100) 1 (7) LAMS 160
Walter et al. [18] (2016) 30 N/D 27 (90) 26 (86.7) 15 (50) LAMS 298
Kahaleh et al. [19] (2016) 35 Benign/malignancy (20/15) 32 (91.4) 31 (89) (25) LAMS, PS 91.5
Irani et al. [20] (2017) 45 Benign/malignancy (29/16) 44 (98) 43 (96) 8 (18) LAMS, PS 215
Dollhopf et al. [21] (2017) 75 Benign (53) 74 (98.7) 71 (95.9) 8 (10.7) LAMS 201
Teoh et al. [22] (2017) 59 Benign (59) 57 (96.6) 53 (94.9) 19 (32.2) LAMS 451
Manta et al. [23] (2018) 226 N/D 215 (95.1) 207 (91.6) 24 (10.6) LAMS 180
Our study 10 Malignancy (10) 9 (90) 8 (89) 4 (40) MS, PS 252

AE, adverse event; LAMS, lumen-apposing metal stent; MS, metal stent; NBT, nasobiliary drainage tube; N/D, not described; PS, plastic stent.