Skip to main content
. Author manuscript; available in PMC: 2019 Jun 4.
Published in final edited form as: Osteoarthritis Cartilage. 2018 Feb 7;26(4):569–579. doi: 10.1016/j.joca.2018.01.012

Table III.

Correlations observed between ultrashort echo time (UTE)-T2* profile characteristics and patient reported outcomes within anterior cruciate ligament reconstruction (ACLR) knees

ROI UTE-T2* profile characteristic KOOS metric r P
cMTP UTE-T2* minimum, L4P Pain −0.35 0.036
Slope middle 50%, AD Symptoms 0.36 0.032
cMFC UTE-T2* maximum, L4P Symptoms 0.43 0.008
pMFC UTE-T2* maximum, L4P Pain −0.41 0.012

Table includes only correlations with P < 0.05. Results of all comparisons are included in Appendix 2.

L4P indicates parameter calculated from four-parameter logistic sigmoidal curve-fit equation.

AD indicates parameter calculated from average derivatives.