Table 3.

Diagnostic performance of mNGS compared with culture and Alere BinaxNow® Streptococcus pneumoniae Antigen test for the detection of Streptococcus pneumoniae

Clinical microbiology tests mNGS
Sensitivity (%) Specificity (%) PPV (%) NPV (%)
Culturea 73.1 88.1 59.4 93.2
Combined testb 70.3 93.9 81.3 89.3

Note: arefers to the blood and/or CSF culture; brefers to culture and or Alere BinaxNow® Streptococcus pneumoniae Antigen test. PPV positive predictive value, NPV negative predictive value