Skip to main content
. 2019 Jun 15;29(2):020710. doi: 10.11613/BM.2019.020710

Table 3. The association between aPTT and clot waveform analysis parameters and acute venous thromboembolism.

Unadjusted Adjusted*
Parameters OR 95% CI P OR 95% CI P
aPTT ratio ≤ 0.9 1.79 0.76 – 4.20 0.182 2.03 0.83 – 4.95 0.119
Min1 > 6.87%/s 8.00 3.59 – 17.83 < 0.001 8.37 3.63 – 19.26 < 0.001
Min2 > 1.05%/s2 5.24 2.48 – 11.07 < 0.001 5.93 2.68 – 13.11 < 0.001
Max2 > 0.91%/s2 4.75 2.15 – 10.48 < 0.001 4.99 2.20 – 11.34 < 0.001
Delta change > 71.63% 18.55 6.36 – 54.15 < 0.001 19.09 6.31 – 57.69 < 0.001
OR – odds ratio. CI – confidence interval. *Adjusted for age, gender and ethnicity. P < 0.05 was considered statistically significant.