Analyte studied, sample type used Methodology used for analysis Platforms used in analysis
Haemoglobin, whole blood Photometric measurement, Cyanmethemoglobin method 3 Part Coulter, Siemens, USA
C-reactive protein, serum Immunoturbidimetric Beckman Coulter, AU 480,USA
Total protein, serum Spectrophotometric, Biuret Beckman Coulter, AU 680, USA
Albumin, serum Spectrophotometric, BCP - Dye Binding Beckman Coulter, AU 680, USA
Ferritin, serum Chemiluminescence /Two-SiteSandwich Immunoassay Advia Centaur XP, Siemens, USA
Soluble transferrin receptor, serum Immunoturbidimetric Beckman Coulter, AU 480, USA
Vitamin A (Retinol), serum HPLC-reverse phase chromatography Thermo Finnigan (spectra system)
Zinc, serum Atomic absorption spectrometry+F18:F28, Shimadzu (AA 7000)
Folate, haemolysate Chemiluminescence / Two-SiteSandwich Immunoassay Advia Centaur XP, Siemens, USA
Vitamin B12, serum Chemiluminescence / Two-SiteSandwich Immunoassay Advia Centaur XP, Siemens, USA
Vitamin 25 (OH) D, serum Chemiluminescence / Two-SiteSandwich Immunoassay Advia Centaur XP, Siemens, USA
Glucose, plasma Spectrophotometric, Hexokinase (UV) Beckman Coulter, AU 680, USA
Glycylated haemoglobin (HbA1C), whole blood Ion Exchange HPLC Variant, Biorad, USA
Total Cholesterol, serum Spectrophotometric, Cholesterol Oxidase Esterase Peroxidase Beckman Coulter, AU 680, USA
High Density Lipoprotein Cholesterol (HDL), serum Spectrophotometric, Direct Measure-Peg/ CHOD Beckman Coulter, AU 680, USA
Low Density Lipoprotein Cholesterol (LDL), serum Spectrophotometric, Direct Measure/ CHOD Beckman Coulter, AU 680, USA
Triglycerides (TG), serum Spectrophotometric, Enzymatic Endpoint Beckman Coulter, AU 680, USA
Creatinine, serum Spectrophotometric, Alkaline Picrate Kinetic (Jaffe’s method) Beckman Coulter, AU 680, USA