Table 1.

Scan parameters. All sequences were acquired at 3T. For each of the sequences, the main acquisition parameters are provided. The PD/−T2‐weighted and FLAIR sequences were used for semi‐automatic lesion segmentation. The DTI, MT and mcDESPOT sequences were used to obtain maps of the microstructural parameters fractional anisotropy (FA), radial diffusivity (RD), magnetisation transfer ratio (MTR), and myelin water fraction (MWF). FLAIR: fluid‐attenuated inversion recovery; FSPGR: fast spoiled gradient echo; SE: spin‐echo; IR: inversion recovery; EPI: echo‐planar imaging; EFGRE: enhanced fast gradient echo; SPGR: spoiled gradient recalled‐echo; bSSFP: balanced steady‐state free precession; IR‐SPGR: inversion recovery spoiled gradient; TE: echo time; TR: repetition time; TI: inversion time

T1‐weighted PD/T2‐weighted FLAIR (T2‐weighted) DTI MT mcDESPOT
Pulse sequence(s) FSPGR SE Se\IR Se\epi EFGRE SPGR, bSSFP, IR‐SPGR
Native resolution (mm3) 1.0 × 1.0 × 1.0 0.94 × 0.94 × 4.5 0.86 × 0.86 × 4.5 1.8 × 1.8 × 2.4 0.94 × 0.94 × 1.9 1.7 × 1.7 × 1.7
Field of view (mm) 256 240 220 230 240 220
Matrix size 256 × 256 × 172 256 × 256 256 × 256 96 × 96 × 36 128 × 128 × 100 128 × 128 × 88
Slices None ‐ 3D 36 (3 mm + 1.5 mm gap) 36 (3 mm + 1.5 mm gap) 57 None ‐ 3D None ‐3D
Total acquisition time (min) 7.5 2 3 12.5 4.5 10
TE, TR (ms) 3.0, 7.8 9.0/80.6, 3000 122.3, 9502 94.5, 16000 1.8, 26.7 SPGR: 2.1, 4.7 bSSFP: 1.6, 3.2 IR‐SPGR: 2.1, 4.7
TI (ms) 450 2,250 IR‐SPGR: 450
Off‐resonance pulse 450°, 2 kHz off
Flip angle (degrees) 20 90 90 90 5 SPGR: [3, 4, 5, 6, 7, 8, 9, 13, 18] bSSFP: [10.6, 14.1, 18.5, 23.8, 29.1, 35.3, 45, 60] IR‐SPGR: [5]