Frequency of endothelialisation and thrombotic metrics across stent platforms (swine coronaries).

3 days (Yorkshire, n=3) 30 days (Yorkshire, n=9) 90 days (Yucatan, n=7)
UHS (n=4) BMS (n=4) DES (N/A) UHS (n=8) BMS (n=8) DES (n=8) UHS (n=7) BMS (n=6) DES (n=6)
Endothelialisation score=4 (optimal result) 0% 0% N/A 100% 100% 62% 100% 100% 100%
Endothelialisation score 3–4 100% 75% N/A 0% 0% 25%** 0% 0% 0%
Endothelialisation score <3 0% 25%* N/A 0% 0% 13%** 0% 0% 0%
Platelet adhesion score=0 (optimal result) 100% 75% N/A 100% 100% 62% 100% 100% 100%
Platelet adhesion score 0–1 0% 25%* N/A 0% 0% 13%** 0% 0% 0%
Platelet adhesion score >1 0% 0% N/A 0% 0% 25%** 0% 0% 0%
Fibrin score=0 (optimal result) 0% 0% N/A 38% 25% 0% 72% 83% 50%
Fibrin score 0–1 100% 100% N/A 62% 75% 38% 28% 17% 50%
Fibrin score >1 0% 0% N/A 0% 0% 62% 0% 0% 0%
* and **:

same single BMS resp. DES devices missing optimal scores in both endothelialisation and platelet adhesion. Score definition. Endothelialisation (0–4) score 4: 100% confluent coverage, score 3: >75% coverage. Thrombotic (0–3) score 0: no platelet adhesion, 1: minimal platelet adhesion. Neointimal fibrin deposition (0–3) score 0: fibrin absent; score 1: infrequent fibrin deposition.

Bold: significant sample percentage showing suboptimal score compared to UHS13.