Skip to main content
. 2017 Nov 27;148(1):154–163. doi: 10.1007/s10562-017-2208-0

Table 5.

Matched rate constants at 90 °C for Scheme 2 for each Pd-loaded MIL-101(Cr) catalyst

Entry Pd loading (wt%) k1 (M−1 h−1) k1,r (h−1) k2 (h−1) k3 (h−1)
1 0.2 8 1 1.1 0.01
2 0.4 8 1 2 0.011
3 0.5 8 1 2.5 0.025
4 1.0 8 1 10 0.1