Skip to main content
. 2019 May 22;12(10):1662. doi: 10.3390/ma12101662

Table 3.

Fittings of compressive strength and curing time under different confining pressures.

Confining Pressure (kPa) Fitting Equation R2
0 qu=115.7+67.6ln(D+1.5) 0.97
50 qu=265.1+32.1ln(D+1.5) 0.83
100 qu=231.7+78.5ln(D+1.5) 0.94
150 qu=239.0+89.9ln(D+1.5) 0.95