Table 2.

Receiver operating characteristic area under the curve (ROCAUC) summary.

Model 11-EXP 3-EXP 11-SW 4-SW
Median IQR Median IQR Median IQR Median IQR
LDA 0.938 0.021 0.946 0.021 0.950 0.006 0.929 0.041
LSTM 0.946 0.006 0.988 0.006 0.999 0.004 0.997 0.003
FCN 0.843 0.040 1.000 0.008 0.997 0.003 0.994 0.001
LSTM-FCN 0.865 0.024 0.994 0.012 0.996 0.005 0.995 0.002
ALSTM-FCN 0.858 0.020 0.996 0.008 0.999 0.002 0.998 0.001