Table 2.

Dose-volumetric parameters of the PTV

DV parameter VMAT IMRT with MR-linac p
D98% (Gy) 59.1 ± 0.3 60.3 ± 1.1 <  0.001
D95% (Gy) 60.0 ± 0.0 60.7 ± 1.2 0.015
D5% (Gy) 64.9 ± 1.3 63.8 ± 1.6 0.026
D2% (Gy) 65.3 ± 1.4 64.2 ± 1.7 0.035
Minimum dose (Gy) 54.6 ± 1.4 58.7 ± 1.3 <  0.001
Maximum dose (Gy) 66.8 ± 1.3 63.8 ± 1.5 < 0.001
Mean dose (Gy) 63.0 ± 0.8 62.3 ± 1.4 0.047
PTV volume (cm3) 27.2 ± 23.5 (ITV + 5 mm) 6.3 ± 7.7 (GTV + 3 mm) < 0.001
Homogeneity index 0.099 ± 0.023 0.062 ± 0.014 < 0.001

Note: DV parameter dose-volumetric parameter, VMAT volumetric modulated arc therapy, IMRT intensity modulated radiation therapy, MR-linac magnetic resonance image linear accelerator, Dn% dose received by at least n% volume of the planning target volume, PTV planning target volume, ITV internal target volume, GTV gross tumor volume