Dose-volumetric parameters of OARs and whole body

OAR DV parameter VMAT IMRT with MR-linac p
Bronchi Maximum dose (Gy) 24.2 ± 21.7 20.4 ± 19.0 <  0.001
V34.8Gy (cm3) 0.5 ± 2.0 0.0 ± 0.1 0.223
Esophagus V30Gy (cm3) 0.0 ± 0.0 0.0 ± 0.0
Heart Maximum dose (Gy) 20.2 ± 16.0 19.1 ± 13.7 0.087
V34Gy (cm3) 0.7 ± 2.4 0.0 ± 0.1 0.168
Ipsilateral lung Mean dose (Gy) 5.7 ± 2.0 5.2 ± 2.1 0.041
V20Gy (cm3) 134.8 ± 81.4 116.8 ± 80.9 0.025
V10Gy (cm3) 275.3 ± 139.3 244.7 ± 140.2 0.047
V5Gy (cm3) 414.7 ± 182.0 358.1 ± 172.9 < 0.001
D1500cc (Gy) 0.13 ± 0.25 0.24 ± 0.37 0.001
D1000cc (Gy) 0.61 ± 1.15 0.76 ± 0.94 0.012
Contralateral lung Mean dose (Gy) 0.9 ± 0.4 1.0 ± 0.6 0.210
V20Gy (cm3) 0.0 ± 0.0 6.6 ± 20.1 0.146
V10Gy (cm3) 0.5 ± 1.6 23.1 ± 44.3 0.029
V5Gy (cm3) 23.4 ± 37.1 49.8 ± 72.1 0.049
D1500cc (Gy) 0.06 ± 0.10 0.11 ± 0.14 0.002
D1000cc (Gy) 0.21 ± 0.28 0.28 ± 0.17 0.046
Rib Maximum dose (Gy) 47.2 ± 16.5 43.0 ± 12.9 0.032
V40Gy (cm3) 7.7 ± 13.0 1.8 ± 3.9 0.008
Skin Maximum dose (Gy) 27.8 ± 9.4 33.0 ± 4.4 0.018
V36Gy (cm3) 0.1 ± 0.4 0.1 ± 0.2 0.167
Spinal cord Maximum dose (Gy) 11.0 ± 5.1 14.5 ± 5.6 0.002
V26Gy (cm3) 0.0 ± 0.0 0.0 ± 0.0
Whole body Mean dose (Gy) 1.2 ± 0.5 0.9 ± 0.3 < 0.001
V50% (cm3) 103.5 ± 82.8 78.7 ± 62.9 < 0.001

Note: OAR organ at risk, DV parameter dose-volumetric parameter, VMAT volumetric modulated arc therapy, IMRT intensity modulated radiation therapy, MR-linac magnetic resonance image linear accelerator, VnGy percent volume receiving n Gy, Dncc dose received by at least n cc volume of the planning target volume, Vn% percent volume receiving n% of the prescription dose