Skip to main content
. 2019 May 17;19(10):2281. doi: 10.3390/s19102281

Table 3.

Accuracy of two-class classification (non-inoculated/infected spikelets) using support vector machine (SVM) for each assessment date using the defined parameters derived from each sensor and combinations of different sensors.

Time [dai] Accuracy [%] of Two-Class Classification
IRT 1 CFI 2 HIS 3 IRT-CFI IRT-HSI CFI-HSI Multi-Sensor (IRT-CFI-HSI)
3 78 56 78 67 67 56 56
5 100 67 78 67 100 78 100
7 78 89 89 78 78 78 78
12 78 89 100 100 100 100 100
17 100 89 100 100 100 100 100
21 78 89 100 89 100 100 100
30 67 78 78 67 89 89 78
Mean 82 79 89 81 90 86 87

1 IRT, infrared thermography; 2 CFI, chlorophyll fluorescence imaging; 3 HSI, hyperspectral imaging