Skip to main content
. 2019 Jun 13;14:142. doi: 10.1186/s13023-019-1116-3

Table 2.

Diagnostic accuracy of nNO + TEM, nNO + HSVM and nNO/HSVM+TEM algorithms

Classification Diagnostic Algorithm
NO+TEM NO+HSVM NO/HSVM+TEM
PCD as PCD (% of PCD) 198 (62%) 273 (85%) 313 (98%)
PCD as non-PCD (% of PCD) 122 (38%) 47 (15%) 7 (2%)
Non-PCD as non-PCD (% of non-PCD) 678 (99.7%) 680 (100%) 674 (99%)
Non-PCD as PCD (% of non-PCD) 2 (0.003%) 0 (0%) 6 (1%)
Net Sensitivity 62% 85% 98%
Net Specificity 99.7% 100% 99%
Net PPV 99% 100% 98%
Net NPV 85% 94% 99%

PPV Positive Predictive Value, NPV Negative Predictive Value