Table 2.
Aspiration materials | Umbilical vein catheterization materials |
• Bulb syringe | • Sterile gloves |
• Wall suction | • Scissors or bistoury blade |
• Suction catheters: 5F or 6F, 8F, 10F, 12F or 14F | • Antiseptic preparation solution (Povidone iodide) |
• 8 Fr nasogastric catheter and 20 mL injector | • Umbilical catheters 3.5 Fr, 5 Fr |
• Meconium aspirator | • Stopcock |
• Injectors – 1, 3, 5, 10, 20, 50 mL | |
• Needles – No. 25, 21, 18 | |
Bag-valve mask materials | Drugs |
• Masks with sizes compatible with terms and reterms | • Adrenaline; 1:10.000 (0.1 mg/mL); prepared by diluting from 1, 0.5, 0.25 mg ampoules (distilled water) |
• Self-inflating bag with a volume of 250-270 mL | • Volume expander; isotonic crystalloid (normal saline or Ringer’s lactate) 100 or 250 mL |
• Oxygen source | |
• Air source | • Dextrose 10% - 250 mL |
• Flowmeter | • Normal saline for washing |
• Oxygen-air mixer and hoses | • Distilled water |
• Pulse oximeter and oximeter probe | |
T-piece resuscitator | |
Intubation materials | Other |
• Laryngoscope and No. 0 (preterm) and | • Gloves, caps and other personal protectors |
No. 1 (term) straight blades | • Cord clamp |
• Spare lamps and batteries for laryngoscope | • Radiant heater |
• Endotracheal tubes – sizes 2.5, 3.0, 3.5, 4.0 mm | • Smooth, hard surface for resuscitation procedure |
• Watch (chronometer optional) | |
• Stylet (optional) | • Heated towels |
• Scissors | • Stethoscope (with drum for newborns preferable) |
• Tape or endotracheal tube holder | • Plaster |
• Gauze with alcohol | • Heart monitor and electrodes (if possible) |
• Carbon dioxide detector (if possible) | • Oropharyngeal cannula (with a size of 0, 00, 000 or a length of 30, 40 and 50 mm) |
• Laryngeal mask | |
• Oropharyngeal cannula | |
For extremely preterm babies | |
• Polyethylene bag (big size) | |
• CPAP cannula with different sizes, ventilator circuit | |
• Transport incubator to maintain the baby’s body temperature during transportation to ward (with ventilator, if possible) | |
• No. 00 laryngoscope blade |
CPAP: continuous positive airway pressure