List of equipment required for resuscitation of the newborn

Aspiration materials Umbilical vein catheterization materials
• Bulb syringe • Sterile gloves
• Wall suction • Scissors or bistoury blade
• Suction catheters: 5F or 6F, 8F, 10F, 12F or 14F • Antiseptic preparation solution (Povidone iodide)
• 8 Fr nasogastric catheter and 20 mL injector • Umbilical catheters 3.5 Fr, 5 Fr
• Meconium aspirator • Stopcock
• Injectors – 1, 3, 5, 10, 20, 50 mL
• Needles – No. 25, 21, 18
Bag-valve mask materials Drugs
• Masks with sizes compatible with terms and reterms • Adrenaline; 1:10.000 (0.1 mg/mL); prepared by diluting from 1, 0.5, 0.25 mg ampoules (distilled water)
• Self-inflating bag with a volume of 250-270 mL • Volume expander; isotonic crystalloid (normal saline or Ringer’s lactate) 100 or 250 mL
• Oxygen source
• Air source • Dextrose 10% - 250 mL
• Flowmeter • Normal saline for washing
• Oxygen-air mixer and hoses • Distilled water
• Pulse oximeter and oximeter probe
T-piece resuscitator
Intubation materials Other
• Laryngoscope and No. 0 (preterm) and • Gloves, caps and other personal protectors
No. 1 (term) straight blades • Cord clamp
• Spare lamps and batteries for laryngoscope • Radiant heater
• Endotracheal tubes – sizes 2.5, 3.0, 3.5, 4.0 mm • Smooth, hard surface for resuscitation procedure
• Watch (chronometer optional)
• Stylet (optional) • Heated towels
• Scissors • Stethoscope (with drum for newborns preferable)
• Tape or endotracheal tube holder • Plaster
• Gauze with alcohol • Heart monitor and electrodes (if possible)
• Carbon dioxide detector (if possible) • Oropharyngeal cannula (with a size of 0, 00, 000 or a length of 30, 40 and 50 mm)
• Laryngeal mask
• Oropharyngeal cannula
For extremely preterm babies
• Polyethylene bag (big size)
• CPAP cannula with different sizes, ventilator circuit
• Transport incubator to maintain the baby’s body temperature during transportation to ward (with ventilator, if possible)
• No. 00 laryngoscope blade