Skip to main content
. 2019 May 7;11(5):822. doi: 10.3390/polym11050822

Table 2.

Variance analysis of response surface quadratic model for the extraction of BS mucilage.

Source Sum of Squares df Mean Square F Value P-Value (Prob > F) Significance
Model 1739.21 14 124.23 13.09 <0.0001 **
A-Temperature 80.81 1 80.81 8.52 0.0140 *
B-Liquid-solid ratio 531.04 1 531.04 55.97 <0.0001 **
C-Time 92.59 1 92.59 9.76 0.0097 **
D-Shear speed 109.16 1 109.16 11.51 0.0060 **
AB 0.74 1 0.74 0.077 0.7859
AC 28.70 1 28.70 3.03 0.1098
AD 0.15 1 0.15 0.016 0.9022
BC 104.74 1 104.74 11.04 0.0068 **
BD 11.61 1 11.61 1.22 0.2922
CD 75.40 1 75.40 7.95 0.0167 *
A2 180.33 1 180.33 19.01 0.0011 **
B2 502.27 1 502.27 52.94 <0.0001 **
C2 343.50 1 343.50 36.20 <0.0001 **
D2 17.53 1 17.53 1.85 0.2013
Residual 104.37 11 9.49
Lack of Fit 103.78 10 10.38 17.76 0.1828 Not significant
Pure Error 0.58 1 0.58
Cor Total 1843.57 25

** Means significant differences (P < 0.01), * Means significant differences (P < 0.05).