Table X.

Results of Simple Linear Regression Analyses for Cochlear Implant Users With Cognitive Scores as Dependent Measures and Age as Predictor

Predictor: Age
B SE(B) β t P R2
Digit span (total digits correct) −0.033 0.327 −0.018 0.10 .92 <0.001
Stroop interference score (ms) 30.574 12.044 0.409 2.54 .016 0.168
TOWRE words (% words correct) −0.005 0.002 −0.393 2.42 .021 0.155
TOWRE nonwords (% nonwords correct) −1.210 0.313 −0.565 3.87 .001 0.319
Raven’s nonverbal reasoning (total correct) −0.420 0.070 −0.728 6.00 <.001 0.530
Fragmented sentences (% words correct) −0.671 0.206 −0.499 3.26 .003 0.249

B = Unstandardized beta; SE = standard error; TOWRE = Test of Word Reading Efficiency.