Skip to main content
. Author manuscript; available in PMC: 2019 Nov 1.
Published in final edited form as: Laryngoscope. 2018 Oct 16;128(Suppl 5):10.1002/lary.27457. doi: 10.1002/lary.27457

Table XXI.

Results of Partial Correlation Analyses for CI and NH Participants Between Spectral Resolution and Each Group’s Cognitive Mediators, Controlling for Age

Partial Correlation (r) With Spectral
Resolution, Controlling for Age
P Value
CI users-cognitive mediator of age on speech recognition
 TOWRE words (% words correct) 0.229 .214
 Raven’s nonverbal reasoning (total correct) 0.238 .198
NH controls-cognitive mediator of age on speech recognition
 Digit span (number digits correct) 0.161 .142
 Stroop interference score (ms) −0.364 .001
 TOWRE nonwords (% nonwords correct) 0.245 .024
 Raven’s nonverbal reasoning (total correct) 0.247 .022

CI = cochlear implant; NH = normal hearing; TOWRE = Test of Word Reading Efficiency.