Skip to main content
. Author manuscript; available in PMC: 2019 Nov 1.
Published in final edited form as: Laryngoscope. 2018 Oct 16;128(Suppl 5):10.1002/lary.27457. doi: 10.1002/lary.27457

Table VIII.

Results of Multiple Linear Regression Analyses for Cochlear Implant Participants With Speech Recognition Scores as Dependent Measures and Both Spectral Resolution and Age as Predictors

Predictors: Spectral Resolution and Age
Dependent Measures B SE(B) β t P R2
Harvard standard sentences (% words correct)
 Predictors 0.221
  Spectral resolution (spectral ripple threshold) 1.702 1.687 0.198 1.01 .322
  Age (yr) −0.502 0.294 −0.334 1.71 .099
PRESTO sentences (% words correct) 0.272
  Spectral resolution (spectral ripple threshold) 6.363 2.692 0.448 2.36 .025
  Age (yr) −0.300 0.470 −0.121 .64 .529
CID words (% words correct) 0.334
  Spectral resolution (spectral ripple threshold) 6.743 2.732 0.439 2.47 .020
  Age (yr) −0.552 0.464 −0.211 1.19 .244

CID = Central Institute of the Deaf; PRESTO = Perceptually Robust English Sentence Test Open-set; B = Unstandardized beta; SE = standard error.