Skip to main content
. 2019 Jun 14;9:8643. doi: 10.1038/s41598-019-45196-x

Table 2.

Distribution of measurements of mean net flow and peak velocity in the different 4D flow sequences GRAPPA and k-t GRAPPA in different measuring planes with p-value, correlation coefficient and limits of agreement.

Net flow [ml/cycle] peak velocity [m/sec]
GRAPPA [ml/cycle] k-t GRAPPA [ml/cycle] Correlation coefficient R/p-value Limits of agreement (LOA) GRAPPA [ml/cycle] k-t GRAPPA [ml/cycle] Correlation coefficient R/p-value Limits of agreement (LOA)
Ascending Aorta

83.54

(±25.03)

88.14

(±26.21)

0.94/<0.0001 −22.9–12.4

1.21

(±0.29)

1.18

(±0.31)

0.60/<0.0001 −0.61–0.64
Aortic Arch

67.34

(±20.75)

68.5

(±21.19)

0.92/<0.0001 −18.6–15.1

1.1

(±0.32)

1.01

(±0.29)

0.65/<0.0001 −0.42–0.64
Descending Aorta

50.26

(±17.12)

49.56

(±17.38)

0.87/<0.0001 −17.3–17.9

1.0

(±0.34)

0.93

(±0.44)

0.91/<0.0001 −0.31–0.44
Descending Aorta - level of diaphragm

42.37

(±18.76)

40.1

(±18.6)

0.83/<0.0001 −21.7–24.2

1.06

(±0.35)

0.92

(±0.34)

0.55/

<0.0001

−0.52–0.78

The given p-values refer to the significance of the correlations.