Skip to main content
. 2019 Jun;60(6):777–785. doi: 10.2967/jnumed.118.217745

TABLE 3.

Comparison of Lesion and Normal-Organ Uptake and Retention for 68Ga-DOTATATE and 64Cu-SARTATE

Measure 68Ga-DOTATATE 64Cu-SARTATE Difference 95% CI P*
Median at 1 h
 Max lesion SUVmax 31.65 41.90 12.45 5.1, 21.4 0.010
 Mean patient SUVmax 23.61 33.32 10.35 5.4, 15.3 0.002
 Liver SUVmean 7.10 7.45 0.30 −0.2, 0.8 0.24
 Spleen SUVmean 20.40 28.25 9.05 4.0, 14.9 0.004
 Kidney SUVmean 13.10 20.98 6.80 5.4, 12.1 0.002
Median at 1 h (68Ga-DOTATATE) or 4 h (64Cu-SARTATE)
 Max lesion SUVmax 31.65 50.50 17.10 9.6, 36.3 0.004
 Mean patient SUVmax 23.61 34.80 12.99 6.3, 27.9 0.004
 Liver SUVmean 7.10 5.90 −1.05 −2.2, 1.0 0.19
 Spleen SUVmean 20.40 35.55 17.50 7.7, 102.2 0.020
 Kidney SUVmean 13.10 18.05 4.86 2.1, 7.0 0.004
*

Paired Wilcoxon test on 10 patients.

CI = confidence interval; max lesion = most intense lesion; mean patient = mean of up to 5 reference lesions.