Skip to main content
. 2010 Oct 29;2(4):272–277. doi: 10.1111/j.1757-7861.2010.00099.x

Figure 5.

Figure 5

(A) Six points were chosen from both sides of the arcuate line. The solid line represents the von Mises stress of points in an intact pelvic ring, and the dashed line represents the reconstructed entire pelvic ring with illustration on the top. (B) Comparison of von Mises stress distribution along the posterior side of the implant (dashed line), which was in almost the same position as the implant sciatic notch and unaffected sciatic notch (solid line).