Table 4.

A comparison of the retinal image quality and intraocular scattering between the two groups at 3 years postoperatively

Parameters ICL group LRS group
OSI 1.28 ± 0.60 (0.23–2.65) 1.79 ± 0.94 (0.73–3.95)
MTFcutoff (cpd) 34.70 ± 9.10 (19.89–51.87) 27.48 ± 8.44 (8.86–41.56)
SR 0.18 ± 0.55 (0.11–0.29) 0.16 ± 0.04 (0.07–0.23)
OV100% 1.15 ± 0.30 (0.67–1.70) 0.90 ± 0.26 (0.35–1.37)
OV20% 0.79 ± 0.27 (0.40–1.40) 0.63 ± 0.18 (0.25–0.97)
OV9% 0.44 ± 0.17 (0.20–0.80) 0.37 ± 0.12 (0.15–0.57)

cpd = cycles per degree, ICL = implantable collamer lens, LRS = laser refractive surgery, MTF cut‐off = modulation transfer function cut‐off frequency, OSI = objective scatter index, OV = optical quality analysis system values, SR = Strehl ratio in two dimensions.

The results are expressed as mean ± SD (range).