Table 3. The risk classification performance of the radiomics models.

Group AUC 95%CI Sensitivity (%) Specificity (%)
UECT
   Training set 0.842 0.763–0.922 71.43 74.07
   Validation set 0.774 0.632–0.916 74.36 72.73
CECT
   Training set 0.741 0.628–0.814 66.67 64.81
   Validation set 0.734 0.597–0.872 62.96 66.67