Skip to main content
. 2019 Jun 24;6(1):e000982. doi: 10.1136/openhrt-2018-000982

Table 2.

Procedure characteristics

Group I
(n=70)
Group II
(n=70)
Group III
(n=70)
Pulmonary vein antrum isolation 70 (100%) 70 (100%) 70 (100%)
Cavo-tricuspid isthmus linear ablation 12 (17%) 12 (17%) 18 (26%)
Supra vena cava isolation 3 (4%) 7 (10%) 6 (9%)
Left atrial posterior wall isolation 1 (1%) 5 (7%) 56 (80%) *
Mitral isthmus linear ablation 2 (3%) 3 (4%) 4 (6%)
Low voltage zone modification 2 (3%) 0 (0%) 1 (1%)
Other atrial tachycardia 2 (3%) 2 (3%) 5 (7%)
Procedure time (min) 251±53 250±58 188±38 †
Fluoroscopic time (min) 25.1±10.0 15.1±7.3 * 13.0±5.4 *
Radiation dose (mGy) 295.0±263.0 109.6±103.5 * 110.1±89.6 *
3D-EMS (CARTO/Ensite/Rhythmia) 64/6/0 46/24/0 ‡ 31/38/1 *
Contact force monitoring catheter 64 (91%) 46 (66%) ‡ 69 (99%)

*p<0.0001.

†p=0.002.

‡p=0.0003.

3D-EMS, three-dimensional electroanatomical mapping systems.