Skip to main content
. 2019 Mar 13;82(1):395–410. doi: 10.1002/mrm.27714

Table 3.

Mean and standard deviation of the RMSE over the whole grid for each acquisition protocol and each of the estimated parameters

RMSE (μσ) f
Da[μm2/ms]
De[μm2/ms]
De[μm2/ms]
c2=f(κ)
SDE 0.14; 0.12 0.74; 0.43 0.51; 0.33 0.33; 0.27 0.13; 0.08
DDE40+20
0.10; 0.10 0.39; 0.30 0.41; 0.31 0.29; 0.25 0.08; 0.07
DDE30+30
0.11; 0.10 0.39; 0.29 0.42; 0.30 0.30; 0.25 0.08; 0.07
DDE20+40
0.11; 0.10 0.40; 0.30 0.43; 0.31 0.31; 0.25 0.08 ; 0.07
DDE0+60
0.20; 0.13 0.72; 0.38 0.65; 0.28 0.46; 0.27 0.18; 0.11