Skip to main content
. 2019 Jun 17;8:e46450. doi: 10.7554/eLife.46450

Table 2. Model fit parameters for Schemes 3 and 4.

Average fit parameters (mean ± S.E.M.) obtained from global fits of Schemes 3 (left column) and 4 (right column) to three pairs of macroscopic WT CFTR current activation/deactivation time courses recorded in response to addition/removal of 0.01x saturated and 1x saturated concentrations of Vx-770 to the cytosolic (bath) solution. * Parameters kin and kout were constrained through kin/kout = Doct/wat(pH=7.1) = 62580. ** Parameters Kd;mem, K0.5;mem, and K0.5;aq were calculated from the fit parameters as described in Materials and methods.

Scheme 3 4
kin (s-1)* 4034 ± 464 9794 ± 531
kout (s-1)* 0.06446 ± 0.00742 0.1565 ± 0.0085
kon' (M-1s-1) 870.3 ± 104.0 3703 ± 627
koff (s-1) 0.007451 ± 0.000871 0.01075 ± 0.00009
kflip (s-1) - 0.04408 ± 0.00583
Po;max/Po;bas 3.935 ± 0.001 3.996 ± 0.007
Kd;mem (µM)** 8.751 ± 1.160 3.106 ± 0.605
K0.5;mem (µM)** 21.13 ± 2.80 7.498 ± 1.460
K0.5;aq (nM)** 0.6752 ± 0.0895 0.6690 ± 0.0955