Skip to main content
. 2019 Mar;57(1):97–104. doi: 10.17113/ftb.57.01.19.5983

Table S1. Melting temperature (Tm) and threshold cycle values of positive controls and their dilutions obtained by CFX96 (40).

Lactobacillus sakei Lactobacillus curvatus
Dilution Tm/°C Threshold cycle Dilution Tm/°C Threshold cycle
LightCycler 480 HRM master kit
1 (78.5±0.1)a (21.7±0.2)a 1 (79.1±0.1)a (21.55±0.07)a
10-1 (78.4±0.0)a (25.09±0.03)a 10-1 (79.0±0.0)a (25.23±0.08)a
10-2 (78.4±0.0)a (28.47±0.09)a 10-2 (79.1±0.1)a (28.52±0.08)a
10-3 (78.4±0.0)a (32.2±0.2)a 10-3 (79.0±0.0)a (32.32±0.03)a
10-4 (78.2±0.0)a (35.9±0.6)a 10-4 (79.0±0.0)a (35.8±0.6)a
Total (78.4±0.1)b Total (80.45±0.03)b
Real-time PCR reagent
1 (79.4±0.0)a (20.3±0.1)a 1 (80.0±0.0)a (20.21±0.04)a
10-1 (79.3±0.1)a (24.07±0.08)a 10-1 (79.8±0.0)a (24.15±0.05)a
10-2 (79.2±0.0)a (28.5±0.1)a 10-2 (79.8±0.0)a (27.8±0.1)a
10-3 (79.2±0.0)a (31.6±0.3)a 10-3 (79.8±0.0)a (31.15±0.04)a
10-4 (79.2±0.0)a (35.3±0.2)a 10-4 (79.8±0.0)a (34.5±0.4)a
Total (79.25±0.09)b Total (79.84±0.08)b

Data represent the mean value±standard deviation (aN=3, bN=15). PCR=polymerase chain reaction