Skip to main content
. 2019 Jun 26;11(6):347–374. doi: 10.4252/wjsc.v11.i6.347

Table 1.

Antibodies used for immunofluorescence and for flow cytometry analysis

Antigen Company Dilution Incubation time
Immunofluorescence staining
CD73 Thermo Fisher Weston, Florida, USA 1:100 1 h
CD90 Abcam Cambridge, UK 1:100 1 h
CD105 Dako Palo Alto, California, USA 1:10 1 h
CD34 1:100 30 min
CD45 1:100 30 min
CD56 1:80 30 min
CD146 Santa Cruz Dallas, Tx, USA 1:25 1 h
PDGFRα 1:25 1 h
PW1 Atlas Antibodies Bromma, Sweden 1:100 1 h
Alexa Fluor 1:700 40 min
488 nm
Donkey anti-mouse
Alexa Fluor Thermo Fisher Weston, Florida, USA 1:700 40 min
488 nm
Donkey anti-rabbit
Alexa Fluor 1:700 40 min
594 nm
Donkey anti-mouse
Alexa Fluor 1:700 40 min
594 nm
Donkey anti-rabbit
Flow Cytometry
CD73 (IgG) APC BD Pharmingen San Jose, California, USA 1:25 30 min
CD90 (IgG) FITC 1:25 30 min
CD105 (IgG) PE 1:25 30 min
CD34 (IgG) FITC 1:25 30 min
CD45 (IgG) APC 1:25 30 min
CD56 (IgG) PE 1:25 30 min
CD146 (IgG) PE 1:25 30 min
Isotype controls: 1:25 30 min
IgG APC
IgG PE
IgG FITC