Skip to main content
. 2019 Jun 17;23:101896. doi: 10.1016/j.nicl.2019.101896

Table 1.

Anatomical and quantitative MRI acquisition details. Axial scans were centered at the level of the C2/C3 disc, which provided full coverage of the C2 and C3 cord levels and partial coverage of C1 and C4. Resolution (RES) and field of view (FOV) values correspond to the Left-Right, Ventral-Dorsal, and Inferior-Superior directions. (TE = Echo time, TR = Repetition time, TSE = Turbo spin echo, FA = Flip angle, SENSE = Sensitivity encoding).

Anatomical Quantitative
Sagittal T2-Weighted
  • 2D Multi-slice

  • TR/TE: 3000/120 ms

  • TSE Factor: 24

  • FA: 90°

  • RES: 0.8x1x3mm

  • FOV: 160x250x36 mm

  • Time: 3 min

Myelin Water Imaging
3D Multi-echo Gradient and Spin Echo (GRASE)
  • Axial orientation, 16 slices

  • 32 Echoes

  • TR/TE: 1500/10 ms

  • RES: 0.75x0.75x5mm

  • FOV: 180x150x40mm

  • Time: 8 min 36 s

Quantitative T1
3D Spoiled Gradient Recalled
  • Axial orientation, 14 slices

  • TR/TE: 5.5/2.7 ms

  • SENSE Factor: 2

  • FA: 2,3,4,6,8,13,18°

  • RES: 0.75x0.75x4 mm

  • FOV: 180x200x56 mm

  • Time: 7x11 s = 1 min 17s

Multi-Echo Gradient Echo
  • 2D Multi-slice

  • Axial orientation, 16 slices

  • TR/TE1/TE2–5: 815/6.6/8.2 ms

  • RES: 0.8x0.8x2.5 mm

  • FOV: 150x150x43.75 mm

  • Time: 5 min

Diffusion Tensor Imaging
  • Axial orientation, 10 slices

  • B-values: 0 & 750

  • 32 directions

  • TR/TE = 3362/68 ms

  • RES:1x1x5mm

  • FOV: 64x64x52mm

  • Time: 4 min 42 s

Quantitative T1
3D Inversion Recovery Spoiled
Gradient Recalled
  • Axial orientation, 14 slices

  • TR/TE/TI: 5.5/2.7/350 ms

  • SENSE Factor: 2

  • FA: 5°

  • RES: 0.75x0.8x8mm

  • FOV: 180x200x56 mm

  • Time: 17 s