Skip to main content
. 2019 Jul 4;5(7):e01946. doi: 10.1016/j.heliyon.2019.e01946

Table 2.

Analytical characteristics determination of AA, DA and UA by the tetra ganciclovir cobalt (II) phthalocyanine/GCE.

Electrodes Methods a A b Ep (mV) c DOL (μmol) Linear regression (Y) (R2) Linear range d Sen (μA μM−1) Ref.
PtAu hybrid film modified electrode CV AA 190 - - - 0.103–0.165mM 0.008 [25]
DA 350 - - - 0.024–0.384mM 0.05
UA 520 - - - 0.02–0.336mM 0.015
[Ni(phen)2]2+/SWCNTs/GCE CV AA 130 - - - 30.0–1547 μM - [38]
DA 334 - - - 1–780 μM -
UA 486 - - - 1–1407 μM -
CoTGPc/GCE CV AA -128 0.33 1.73 (AA)+3.47 0.999 2–10 μM 1.73 THIS WORK
DA 245 0.03 2.54 (DA)+3.76 0.999 2–10 μM 2.54
UA 623 0.10 1.55(UA)+11.20 0.998 2–10 μM 1.55
DPV AA -131 0.50 2.88 (AA)+4.199 0.998 2–12 μM
2–12 μM
2–12 μM
2.88
2.91
2.99
DA 250 1.20 2.91 (DA)+4.20 0.999
UA 610 0.50 2.99(UA)+4.26 0.999
CA AA -200e 5.33 0.421 (AA)+1.746 0.995 5–45 μM 0.42
DA 400 6.50 0.831 (DA)+0.757 0.998 5–45 μM 0.83
UA 600 5.00 0.902(UA)+2.373 0.994 5–45 μM 0.90
a

Analytes.

b

Peak potential.

c

Detection limit.

d

Sensitivity.

e

Applied potential.