Skip to main content
. 2019 May 21;20(7):15–27. doi: 10.1002/acm2.12623

Figure 3.

Figure 3

Comparison of the dose‐volume‐histogram (DVH) indices between intensity‐modulated proton therapy (IMPT) and volumetric‐modulated arc therapy (VMAT) treatment plans in the nominal scenario. (a) clinical target volume (CTVhigh) D2cm3 and CTVlow D95% normalized to the prescription dose. (b) CTVhigh D5%–D95% normalized to the prescription dose. (c) Kidney V18Gy[RBE] and liver V30Gy[RBE] in relative volume. (d) Absolute volume stomach V45Gy[RBE] in absolute volume. (e) Lung Dmean, cord Dmax and D0.03cm3 , heart Dmean, and liver Dmean in absolute dose. (f) Lung V5Gy[RBE] and V20Gy[RBE], heart V20Gy[RBE], V30Gy[RBE] and V40Gy[RBE] in relative volume. In each box plot, the five horizontal lines from top to bottom are the maximum, third quartile, median, first quartile, and minimum value of the corresponding DVH index for the whole group excluding the outliers respectively. The grey points are the outliers as defined in Statistical Analysis subsection. Numbers at the top of the columns are P‐values from Wilcoxon rank sum testing. The blue boxes are the IMPT results and white boxes are the VMAT results. Abbreviations: RBE = relative biological effectiveness.