Table 1.

Flow Measurement Parameters

Spiral 4D Cartesian 4D
Echo time/TR 3.7/12 ms 3.4/5.8 ms
Number of interleaves 10
Readout duration 5 ms 2.5 ms
SENSE factor 1 2
Segmentation factor 1 2
FOV 280 × 280 mm2 235–280 × 280 mm2
Matrix size 100 × 100 84–100 × 100
Slices* 36–40 36–40
Voxel size 2.8‐mm isotropic 2.8‐mm isotropic
Temporal resolution 48–48.8 ms 46.4–46.5 ms
Flip angle 6.5°
Velocity encoding 120 cm/s 120 cm/s
Nominal scan time 460–510 RR intervals 1012–1326 RR intervals
Actual scan time (without patients, mean + SD) 13 ± 3 min 31 ± 7 min

*Reconstructed slices. A slice oversampling factor of 27% was used to avoid foldover.

FOV = field of view; SENSE, sensitivity encoding; SD, standard deviation; TR, repetition time; RR, R‐wave to R‐wave.