Measurements of the modulation profiles in sPCA+CCA, PCA+CCA, parallel ICA and sCCA.

Methods ECM VBM Correlation ρ Classification accuracy
pcorr AUC pcorr AUC
sPCA+CCA 3.4 × 10−4 0.78 2.6 × 10−4 0.81 0.78 0.68
PCA+CCA 2.9 × 10−2 0.71 2.0 × 10−3 0.73 0.48 0.61
Parallel ICA 0.10 0.68 1.8 × 10−3 0.75 0.27 0.58
sCCA 1.3 × 10−2 0.70 1.6 × 10−2 0.70 0.80 0.60

sCCA obtains the highest correlation due to overfitting, but has very low values in AUC. sPCA+CCA has largest AUC and a large correlation indicating that this method is superior to the other 3 methods. pcorr denotes the p value for group discrimination with multiple comparison correction. The group classification accuracy is obtained by running quadratic discriminant analysis on modulation profiles from both modalities. The most significant p-value and the largest value for each measurement are in bold font.