Published in final edited form as: Laryngoscope. 2008 Apr;118(4):748–752. doi: 10.1097/MLG.0b013e31815fdeee

TABLE I.

Linear Regression Analysis of Pressure vs. Frequency and Amplitude Squared for the Physical Model.

Trial Tube Diameter (mm) Length (cm) Hole Location on Tube* Slope (cmH2O s2/m2) X-Intercept (cmH2O) Standard Error R Value
1 1.6 14.5–16 Midpoint 84.2 −0.27 2.32 0.984
2 1.6 14.7 Midpoint 92.9 0.24 1.72 0.998
3 1.6 19 Midpoint 93.6 0.71 1.55 0.999
4 1.6 23 Midpoint 84.8 −0.45 1.43 0.993
5 1.6 15.9 Midpoint 79.9 0.83 2.20 0.989
6 1.6 15.9 One-third point 79.8 0.68 2.43 0.976
7 1.6 15.9 One-sixth point 107.6 −0.06 5.35 0.976
8 3.2 21.8 Midpoint 96.8 0.30 3.50 0.991
All data 89.4 0.00 (set) 0.92 0.983
Theoretical average 100.75
Theoretical peak 201.5
*

Relative to end connected to water container;

Sine = 0.5 in equation three;

Sine = 1 in equation three.