Table 1.
Quantitative (with standards) determinations of concentrations | |||
---|---|---|---|
Element | 24MgO | 26MgO | Estimated limits of detection |
ppm | ppm | ppm | |
Ag | 10 | 2 | 0.2 |
B | - | - | 0.2 |
Cd | - | - | 1. |
Cr | - | - | 2. |
Cu | 1 | <1 | 0.1 |
Fe | <1 | <1 | 0.5 |
In | 1 | - | 1. |
Pb | - | - | 2. |
Mn | - | - | 0.5 |
Ni | - | - | 1. |
Sn | - | - | 1. |
Si | <1 | <1 | 0.5 |
Ti | 1 | - | 1. |
V | - | - | 5 |
Zn | - | - | |
Semiquantitative (without standards) estimates of concentration ranges | |||
% | |||
0.0001 −0.001 | |||
<0.0001 | |||
<0.0001 | |||
- |
Notes: dash (–), not detected; <, less than.