Skip to main content
. 2019 Jun 1;9(6):127. doi: 10.3390/brainsci9060127

Table 3.

BCI system performance for self-paced motor imagination.

Participant True Positive Rate (%) Number of False Positive Detections per Minute Duration of the BCI Intervention (min) Total Number of Movements Performed
1 74 0.8 12 68
2 79 0.2 14 63
3 77 1.0 7 65
4 77 0.4 19 65
5 72 2.0 15 69
6 74 0.8 13 68
7 78 1.0 14 64
8 81 2.0 11 62
9 72 0.4 19 69
10 78 1.7 16 64
11 72 1.5 11 69
12 69 1.3 12 72
13 70 0.3 21 71
14 74 1.2 9 68
15 79 2.7 13 63
Mean ± Std 75 ± 3 1.2 ± 0.7 14 ± 4 67 ± 3