Skip to main content
. 2019 Jun 20;10(6):468. doi: 10.3390/genes10060468

Table 3.

Accuracy of consensus sequences generated by combining three iterations of the ONTrack pipeline. For each sample, we show the number of properly reconstructed positions over the alignment length and (in parentheses) the percentage accuracy of the consensus sequences for each of the three iterations, the accuracy of the final consensus sequence generated based on the majority rule from the three iterations and the number of iterations supporting it.

Sample ID Consensus Accuracy Read Set 1 Consensus Accuracy Read Set 2 Consensus Accuracy Read Set 3 Final Consensus Accuracy Iterations Supporting the Final Consensus
BC01 650/651 (99.85%) 651/651 (100%) 650/651 (99.85%) 650/651 (99.85%) 2/3
BC02 656/656 (100%) 657/657 (100%) 657/657 (100%) 657/657 (100%) 3/3
BC03 647/647 (100%) 646/647 (99.85%) 646/647 (99.85%) 647/647 (100%) 1/3
BC04 606/606 (100%) 606/606 (100%) 606/606 (100%) 606/606 (100%) 3/3
BC05 656/656 (100%) 656/656 (100%) 657/658 (99.85%) 656/656 (100%) 2/3
BC06 576/576 (100%) 575/576 (99.83%) 574/575 (99.83%) 575/576 (99.83%) 2/3
BC07 535/536 (99.81%) 536/536 (100%) 536/536 (100%) 536/536 (100%) 2/3