Skip to main content
. Author manuscript; available in PMC: 2020 Jan 1.
Published in final edited form as: Ophthalmic Physiol Opt. 2019 Jan;39(1):53–62. doi: 10.1111/opo.12599

Table 1.

Composite binocular function score calculation

Stereoacuity test outcome BF score
Randot stereoacuity test
 40 arc sec 1.6
 60 arc sec 1.8
 100 arc sec 2.0
 200 arc sec 2.3
 400 arc sec 2.6
 800 arc sec 2.9
Randot butterfly test
 2000 arc sec 3.3
Worth 4 dot
 Simultaneous perception or second degree fusion (reports four or five dots) 4.0
 Suppression (reports two red or three green dots) 5.0