Skip to main content
. 2019 Jun 21;12(12):1998. doi: 10.3390/ma12121998

Table 1.

Best efficiencies reported for each type of configuration employing numerous electrolytes.

DSSC Configuration Electrolyte Dye Charge Transfer Resistance (Ω-cm2) PCE (%) ref.
Front illumination
Glass (conventional) [Co(phen)3]2+/3+ ADEKA + LEG4 Not reported 14.3 [15]
Polymer bifacial I/I3 N3 0.66 6.97 [104]
Metal CE–Glass PE [Co(bpy)3]2+/3+ Z907 8.0 5.0 [105]
Metal CE–Polymer PE I/I3 N719 2 5.29 [106]
Rear illumination
Metal PE–Glass CE I/I3 N719 Not reported 9.2 [107]
Metal PE–Polymer CE I/I3 N719 Not reported 8.6 [68]
Special
Monolithic I/I3 N719 Not reported 9.5 [108]
Solid state [Cu(tmby)2]2+/1+ XY-1 Not reported 13.1 [18]