Table 1.
Summary of Specific Absorption Rate (SAR), Intrinsic Loss Power (ILP) calculations, and temperature increase after 60 s exposition time, ΔT, for the different samples tested [inorganic Magnetic Nanoparticles (MNPs) and MamC-medianted Biomimetic Magnetic Nanoparticles (BMNPs)], and the field frequencies indicated.
| System | Frequency f [kHz] | SAR [W/g] | ILP [nHm2kg−1] | ΔT [°C] | 
|---|---|---|---|---|
| MNPs | 197 | 64 ± 5 | 1.01 ± 0.07 | 20.2 ± 0.2 | 
| 230 | 80 ± 5 | 1.04 ± 0.06 | 25.2 ± 0.2 | |
| 280 | 87 ± 6 | 0.96 ± 0.06 | 28.3 ± 0.2 | |
| BMNPs | 197 | 32 ± 3 | 0.50 ± 0.04 | 11.6 ± 0.2 | 
| 230 | 36 ± 3 | 0.47 ± 0.04 | 12.9 ± 0.2 | |
| 280 | 47 ± 3 | 0.52 ± 0.03 | 16.7 ± 0.2 | |
| 25 B + 75 M | 197 | 73 ± 3 | 1.15 ± 0.05 | 28.5 ± 0.2 | 
| 230 | 83 ± 3 | 1.08 ± 0.04 | 30.5 ± 0.2 | |
| 280 | 96 ± 2 | 1.26 ± 0.03 | 34.1 ± 0.2 | |
| 60 B + 40 M | 197 | 57 ± 4 | 0.90 ± 0.06 | 18.1 ± 0.2 | 
| 230 | 62 ± 6 | 0.81 ± 0.07 | 21.6 ± 0.2 | |
| 280 | 75 ± 8 | 0.82 ± 0.09 | 27.5 ± 0.2 |