Skip to main content
. 2019 Jul 18;14(7):e0220014. doi: 10.1371/journal.pone.0220014

Table 7. Spray drift deposition estimations with 95% confidence intervals (CI 95%) as influenced by downwind distance and nozzle type (pooled herbicides) using a log-logistic non-linear regression model in the spray particle drift study.

Nozzlea Distance Spray depositionb CI 95%
m _________________________ % _________________________
TP95015EVS 1.0 32.3 (31.1–33.5)
1.5 22.8 (22.1–23.5)
2.0 17.4 (16.8–18.0)
2.5 13.9 (13.3–14.5)
3.0 11.5 (10.9–12.1)
4.0 8.5 (7.9–9.1)
5.0 6.7 (6.1–7.2)
7.0 4.6 (4.1–5.1)
12.0 2.5 (2.1–2.8)
AI95015EVS 1.0 11.4 (10.1–12.8)
1.5 6.8 (6.1–7.5)
2.0 4.7 (4.0–5.3)
2.5 3.4 (2.8–4.1)
3.0 2.7 (2.1–3.3)
4.0 1.8 (1.3–2.4)
5.0 1.3 (0.9–1.8)
7.0 0.8 (0.5–1.2)
12.0 0.4 (0.2–0.6)

aTeeJet Technologies, Spraying Systems Co., Glendale Heights, IL.

bSpray drift deposition (%) in relation to the applied rate of 140.3 L ha-1.