Skip to main content
. 2019 Jul 25;7(Suppl 1):44. doi: 10.1186/s40635-019-0241-6

Table 2.

AUROC and ROC-derived cutoffs for ARDS and their diagnostic accuracy measures

Score AUROC Optimal cutoff Sensitivity Specificity PPV NPV
Composite
 Global 0.91 (0.86–0.95) 15 80.0% (63.1–91.6) 88.9% (81.8–94.0) 68.3% (55.7–78.7) 93.7% (88.4–96.7)
 Anterolateral 0.91 0.85–0.97) 5 88.6% (73.3–96.8) 82.9% (74.8–89.2) 60.8% (50.6–70.2) 96.0% (90.6–98.4)
Regional
 Anterior 0.84 (0.76–0.92) 2 74.3% (56.7–87.5) 86.3% (78.7–92.0) 61.9% (49.8–72.7) 92.0% (86.4–95.2)
 Lateral 0.89 (0.83–0.95) 4 85.7% (69.7–95.2) 80% (72.0–87.1) 56.6% (46.9–65.8) 95.0% (89.3–97.7)
 Posterior 0.85 (0.78–0.91) 7 80.0% (63.1–91.6) 76% (67.3–83.5) 49.8% (41.0–59.0) 92.7% (86.7–96.1)

Data is reported as value (95% confidence interval)

AUROC area under the receiver operating characteristics curve, PPV positive predictive value, NPV negative predictive value